Square socket.
Equipped with a wide variety of square and round sockets,
Surface connection and back connection.
With a finger touch protection type.
With the fixed bracket, PYF cross tab.
Add no screw series. C500-CT Special I/O Unit High-speed Counter Unit 20 kcps 4 pts C500-CT041.Number of phases: Single-phase .
Insulation method: Phototriac coupler MKS3PI-V-2 AC230.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC
MKS3PI-V-2 AC230
Zero cross function: No.
Applicable load: 35 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents MKS3PI-V-2 AC230. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output MKS3PI-V-2 AC230.
Control mode: standard or heating cooling .
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer MKS3PI-V-2 AC230.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication MKS3PI-V-2 AC230.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
MKS3PI-V-2 AC230 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MKS3PI-V-2 AC230&select=5