Cable length L: A, 15.0 m; B, 14.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Appearance: Round/Projection type LED voltage-reduction lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NC.
Lighting: LED .
Operating voltage: 100 VAC MM4XP-NC01 DC220.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue)
MM4XP-NC01 DC220
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks MM4XP-NC01 DC220.
Finger protection mechanism on Switch Unit provided as a standard feature .
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Shape: rectangle.
Protection structure: IP40.
Action: alternate.
Operation Department color: red.
Column length 18mm, circular F8 series MM4XP-NC01 DC220.
High brightness and with uniform light .
Round type easy opening.
Small and operation feel good. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV MM4XP-NC01 DC220.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation MM4XP-NC01 DC220.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
MM4XP-NC01 DC220 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MM4XP-NC01 DC220&select=5