I/O classification: Counter Unit.
External I/O points: Inputs: 1, Outputs: 2.
I/O connections: Terminal block.
Operating mode: Linear counter.
A Counter Unit Supporting Encoder,
Input for Use with MULTIPLE I/O TERMINAL.
High-speed pulse with counting speed of 50 kHz.
Counting can be set to a multiplication factor of 1 or 4 .
Wide range of measurement: -8,388,608 to 8,388,607 MS4800WS-2040.
One external input and two external outputs are available
MS4800WS-2040
DIN track mounting. Type: rectangle.
Screen mode: 2 short axis segmentation.
Light way: LED.
Power supply voltage: DC24V.
Operating part of the left color: yellow.
Operating Department right color: yellow MS4800WS-2040.
Square 40mm body of the indicator light series .
The same type as the A3S series button switch.
Easy to install from the front panel and no tools to carry out the lamp replacement. Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: SPDT.
Lighting: LED; 5 VDC .
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted MS4800WS-2040.
Pushbutton Switches.
Excellent operating sensitivity .
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Name: Analog I/O Slave Units.
Specifications: Analog inputs;
4 inputs.
Standards: CE, U, U1, C, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily madde with CompoNet MS4800WS-2040.
Wiriing material cost can be reduced .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . MS4800WS-2040.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
MS4800WS-2040 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MS4800WS-2040&select=5