Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work MY2 AC6.
Ideal for the thermal input devices of Temperature Controllers
MY2 AC6
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Category: built-in diode (DC).
Contact form: 4DPDT.
Structure: insert / solder terminal MY2 AC6.
Indicator: no light .
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: AC6V AC6V, MY2-J on behalf of the rated voltage of the coil.
Upgraded version of the small power relay, there are a variety of models, suitable for a variety of sequential control and power applications. Input capacity: 32 points.
Internal I/O common: PNP MY2 AC6.
ON voltage: 15 VDC min . (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors MY2 AC6.
A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software MY2 AC6.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
MY2 AC6 Operation manual / Instructions / Catalog download link: