Actuator: Adjustable rod lever 25 to 140 mm.
Item: Hermetic seal, Molded terminals, -139 models; Basic.
Pretravel (PT): 15±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches MY2NJ-D2 DC100/110.
Standard-feature gold-clad crossbar contacts provide high reliability
MY2NJ-D2 DC100/110
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC MY2NJ-D2 DC100/110.
Contact your OMRON representative for information on approved models .
Sensing method: BGS reflective (fixed distance).
Connection method: Pre-wired (2 m).
Sensing distance: 10 to 200 mm.
Model: PNP output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits MY2NJ-D2 DC100/110.
Certified by Ecolab Europe . Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the suupport software (VVer MY2NJ-D2 DC100/110.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication MY2NJ-D2 DC100/110.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
MY2NJ-D2 DC100/110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MY2NJ-D2 DC100/110&select=5