Release key type: Special release key.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns MY4NJ-CR AC100/110.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
MY4NJ-CR AC100/110
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection MY4NJ-CR AC100/110. Unit: CPU Units.
Name: LED type without display (See note 1 . ).
No. of I/O points: 20.
LCD display: NO.
Power supply voltage: 12 to 24 VDC.
Inputs: 12, 12 to 24 VDC.
Outputs: 8, Relays.
Buttons, calendar, and clock: NO.
Analog input: Yes.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high) MY4NJ-CR AC100/110.
Easy programming is available using the LCD and operation,
buttons . (See note 1.).
This single Unit easily provides relay, timer, counter, and time,
switch functions.
Expansion is easy with Expansion I/O Units, allowing up to 44,
I/O points. (See note 2.).
Economy-type and Communications-type CPU Units have been,
added to series.
Improved Weekly Timers (See note 1.).
Increased timing accuracy with a monthly deviation of ±15 s,
max. Multiple-day operation and pulse output operation have,
been added.
Select from two power supply options:
100 to 240 VAC or 12 to 24 VDC. Specifications: Input, PNP (- common), 16 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintennance and troublesshooting capabilities MY4NJ-CR AC100/110.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required forr iinput devices such as sensors MY4NJ-CR AC100/110.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
MY4NJ-CR AC100/110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MY4NJ-CR AC100/110&select=5