Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0 . 7 m3/min.
Maximum static pressure: 50 Hz, 25 MYQ4ZN AC200/220. 0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB
MYQ4ZN AC200/220
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series MYQ4ZN AC200/220.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Outputs: Time-limit contact and instantaneous contact MYQ4ZN AC200/220.
Supply voltage: 100 to 120 VAC; 200 to 240 VAC .
8-pin models.
DIN 48 × 48-mm Star-delta Timer.
A wide star-time range (up to 120 seconds) and star-delta.
transfer time range (up to 1 seconds). Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Light gray.
Output: SPDT.
Lighting: LED; 5 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made wwith CompoNet MYQ4ZN AC200/220.
Wiriing material cost can be reduced .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . MYQ4ZN AC200/220.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
MYQ4ZN AC200/220 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MYQ4ZN AC200/220&select=5