Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 1 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC) .
Product lineup includes models with distance setting without,
influence of color
NE1A-SCPU01-EIP
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Type: 1a1b welding terminal.
Shape: round.
Type: small load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC5V NE1A-SCPU01-EIP.
Operation Department color: green .
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling NE1A-SCPU01-EIP.
Auxiliary output points: 2 points .
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through thee support software (VVer NE1A-SCPU01-EIP.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication NE1A-SCPU01-EIP.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
NE1A-SCPU01-EIP Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=NE1A-SCPU01-EIP&select=5