Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 24V.
Output current: 6.5A.
Alarm output: leakage type.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device .
Built in support for determining the abnormal causes of the new under voltage detection function
NX-ID4342
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free NX-ID4342.
Humanized design of anti - shedding screw for terminal stage .
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards NX-ID4342. (200V input)
High harmonic current limit: EN61000-3-2 . (except for type 15/30W)
"Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) (See note 2.).
Auxiliary output: None.
Functions: Heater burnout alarm, None; Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temmperature control for up to 2 groups NX-ID4342.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJJ1 Models NX-ID4342. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.
NX-ID4342 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=NX-ID4342&select=5