Name: RS-422A Converter.
Specifications:
Converts RS-233C to RS-422A/RS-485.
Standards: UC1, N, L, CE.
The RS-232C port of the SYSMAC series,
can be changed into RS-422A/485 port.
The CJ1W-CIF11 RS-422A Converter connects,
directly to a CS/CJ-series RS-232C port and,
converts RS-232C to RS-422A/485 . Time specification: Inverse type A165L-AWA-12D-1.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC
A165L-AWA-12D-1
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase A165L-AWA-12D-1.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions A165L-AWA-12D-1. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Number of beams: 74.
Protective height: 1115mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standarrd e-CON connectors A165L-AWA-12D-1.
A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software A165L-AWA-12D-1.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
A165L-AWA-12D-1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A165L-AWA-12D-1&select=5