A New Monoblock Multiple Limit Switch.
Incorporating a Head Box with a Tough.
Head and Ensuring High Sealing.
Performance and a Mechanical.
Durability of 5,000,000 Operations.
Used for the sequential control of a variety of engineering.
machines and belt conveyor lines.
Built-in oil filter shuts out oil and water .
Approved by EN, IEC (Ground terminal models only A165L-JYA-24-1. ) and,
CCC (Chinese standard)
A165L-JYA-24-1 Ask your OMRON representative,
for information on approved models.
Ground terminal models bear the CE mark. Appearance: Knob-type Selector Switch A22W,
LED lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Manual A165L-JYA-24-1.
Output: SPST-NO + SPST-NC.
Operating voltage: 24 VAC/VDC .
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals A165L-JYA-24-1.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). No. of notches: 3 notches.
Output: DPDT.
Reset method: Manual.
Lighting method: LED.
Separate Construction with Cylindrical.
16-dia. Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads.
Oil-resistant IP65 models,
Conforms to EN60947-5-1. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easiily because operation time,
is indicated from the start of operation A165L-JYA-24-1.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions A165L-JYA-24-1. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.