Product name: Split type CT, Connector: For connecting the branch cable,
Cable length: 0.2 m.
Power supply: Battery/DC cable.
Easy and Quick "Checking Power"at the Worksite. Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2 A22-GG-02A.
Item: Momentary operation (Self-resetting).
Separate Construction with
A22-GG-02A
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1 A22-GG-02A. Classification: the built-in CR components (only AC220/240V, AC200/220V, AC100/110V, AC110/120V) .
Contact form: 4DPDT.
Structure: insert / solder terminal.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: AC6V AC6V, MY2-J on behalf of the rated voltage of the coil.
Upgraded version of the small power relay, there are a variety of models, suitable for a variety of sequential control and power applications A22-GG-02A. Cable: With cable.
Connector: Connectors on both cable ends.
Cable length: 0.5 m.
Minimum order: 10.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater conttrol methods,
including OON/OFF control, phase control, and cyclic control A22-GG-02A.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads A22-GG-02A.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
A22-GG-02A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22-GG-02A&select=5