Rugged Rotary Encoder.
Incremental model.
External diameter of 60 mm.
Resolution of up to 1000 ppr.
IP65 oil-resistance with strong shaft.
Radial: 120 N, Thrust: 50 N. E3F3-T61M detection methods: the firing pattern,
Wire lead out type,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyContact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A)
A22-MG-01M
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: SPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted A22-MG-01M.
Pushbutton Switches .
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Number of beams: 10.
Protective height: 245mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors A22-MG-01M.
The muting function is enabled simply with Muting Key Cap .
Comes standard with interlock and auxiliary output functions. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, tto see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV A22-MG-01M.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm fflexible contact output A22-MG-01M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
A22-MG-01M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22-MG-01M&select=5