Outputs: Time-limit contact and instantaneous contact .
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
A wide star-time range (up to 120 seconds) and star-delta,
transfer time range (up to 1.0 seconds).
Setting rings (order separately) to enable consistent settings,
and to limit the setting range .
Panel Covers (order separately) to enable various panel designs A22-TW-20M.
Approved by UL, CSA, CE and CCC
A22-TW-20M Appearance: Round/Full-guard type LED lighting,
(without Voltage Reduction Unit) A22L-G.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue) A22-TW-20M.
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type A22-TW-20M.
(round-type) crimp terminals .
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Element type: R (See note 2.).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 50 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Output method: Analog resolution: 1/6000.
Analog Inputs: 4.Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M : 8m.
A Wide Variety of High-prrecision A22-TW-20M.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teempperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal A22-TW-20M.
A22-TW-20M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22-TW-20M&select=5