Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK A22EL-M-T2-01.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
A22EL-M-T2-01 Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0 A22EL-M-T2-01. 5%),
Analog input: ±0 . 2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter A22EL-M-T2-01.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 75 A, 100 to 240 VAC.
Rated input voltage: 100 to 240 VAC.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification). Appearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Rinng) A22EL-M-T2-01.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type A22EL-M-T2-01.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
A22EL-M-T2-01 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22EL-M-T2-01&select=5