Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available A22L-DW-T2-10M. )
M12-connector models are also available, saving on labor and,
simplifying replacement
A22L-DW-T2-10M
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC A22L-DW-T2-10M. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A) .
Operation: Alternate operation (Self-holding).
Case color: Light gray.
Output: DPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting) A22L-DW-T2-10M.
included in lineup . Direction of Operation Key insertion: Vertical.
Cable length: 1 m.
3NC (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock.
IP67 degree of protection. Inputs: 8I/O link input bits.
Outputs: 8I/O link input bits.Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 5 A.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitoor that A22L-DW-T2-10M.
conform to UUL Class 2 Output standards .
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) A22L-DW-T2-10M.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
A22L-DW-T2-10M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22L-DW-T2-10M&select=5