Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped/L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
DC: Minimum order, 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort A22L-TA-T2-10A.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
A22L-TA-T2-10A
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on A22L-TA-T2-10A.
Connectors with Cables are UL certified .
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents A22L-TA-T2-10A.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) .
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program coommunication A22L-TA-T2-10A.
The usee of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) .
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthee basic function is complete A22L-TA-T2-10A.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).