Power supply: AC power supply.
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.Name: CJ1 Special I/O Unit.
Specifications: Type of communications,
Remote I/O communications, Message communications;
Maximum number of I/O points per Master Unit,
Word Slave Units: 1,024 inputs and 1,024 outputs,
(2,048 I/O points total)Bit Slave Units:
256 inputs and 256 outputs (512 I/O points total)
A22R-TA-20A
No. of unit numbers allocated: 1, 2, 4, or 8.
Current consumption : 5V, 0.4A; 24V,--.
Standards: CE, U, U1, L, N.
NJ/CJ-series CompoNet Master Units Increase,
the Range of Applicability of Sensors and Actuators.
The NJ/CJ-series CompoNet Master Unit manages,
the CompoNet network, controls communications,
between the Controller and Slave Units,
and handles I/O data and message data A22R-TA-20A. Name: Safety Controller.
Number of I/O: Safety inputs, 10; Test outputs, 6;
Safety outputs, Solid-state outputs: 16; Standard outputs, --.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery A22R-TA-20A.
Three types of CPU with different I/O size to suit the application .
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, verification, standardization and reusage of,
safety control by unique programming software.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventiive maintenance function is increased,
Further performance improvement A22R-TA-20A.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV A22R-TA-20A.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
A22R-TA-20A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22R-TA-20A&select=5