Subminiature Models.
Capable of Large-capacity.
load of 7A.
Snap-action switch allows large-capacity.
switching (7A at 250 VAC) in spite of its small size.
Particularly suitable as control switches for,
applications where there are restrictions on,
installation space and weight. Wiring: Screw terminals .
Mounting method: Surface mounting/track mounting A22RL-TW-12A-11M.
Daily Time Control with Simple Operations,
Specify the operation days
A22RL-TW-12A-11M
(However, you can set only one pattern of operation days,
and specified days.)
Up to 12 ON/OFF operations (24 for pulse-output operation).
Special holidays can be handled easily with the holiday,
setting function A22RL-TW-12A-11M.
Adjustments for sudden schedule changes can be made eas,
ily using output override and automatic return operation .
The operation program can be checked easily with the program check function.
Enables pulse output operation and summer time setting.
Incorporates finger-safe terminals.
Conforms to UL, CSA, and CE marking.
Meets a variety of mounting requirements: flush mounting,
surface mounting, and DIN track mounting A22RL-TW-12A-11M. Product name: N@@-type CPU Units with 20 I/O Points .
Specifications: Power Supply, 24 VDC; Inputs, 12; Outputs, 8;
Output type: Transistor (sinking).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.23A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1. A22RL-TW-12A-11M.
Current consumptiion : 5V, 0 .36A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485,, aand the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol A22RL-TW-12A-11M.
A22RL-TW-12A-11M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22RL-TW-12A-11M&select=5