Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system A22RW-2AY-24A-02.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
A22RW-2AY-24A-02
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error A22RW-2AY-24A-02. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A) .
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: DPDT.
Lighting: Incandescent lamp; 14 VDC/VAC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting) A22RW-2AY-24A-02.
included in lineup . Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
1NC/1NO (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE markiing A22RW-2AY-24A-02.
Certified by UUL and CSA standards .
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn pprevented by special Operation Key A22RW-2AY-24A-02.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).
A22RW-2AY-24A-02 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22RW-2AY-24A-02&select=5