Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort .
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
A22RW-3MA-24A-02
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on A22RW-3MA-24A-02.
Connectors with Cables are UL certified .
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Isolation: Phototriac.
Zero cross function: Yes.
Indicator: No.
Rated output load: 20 A at 100 to 240 VAC.
Rated input voltage(See note 1, 2.): 5VDC, 12VDC, 24VDC.
Compact, Low-cost, SSR Switching 5 to 20 A.
Wide load voltage range: 75 to 264 VAC. Both 100-V and,
200-V loads can be handled with the same model A22RW-3MA-24A-02.
Dedicated, compact aluminum PCB and power elements used .
Built-in varistor effectively absorbs external surges.
Quick-connect #110 input terminals and #250 output,
connections. (#187 input terminals and #250 output,
connections are available.).
“-US” models certified by UL, CSA, and IEC/EN (TÜV). Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Cable Specifications: Fire-retardant, Robot cable.
No. of connector poles: 4.
Cable connection direction: Straight.
No. of cable cores: 4.
Cable outer diameter: 6.0 mm dia.
Cable core cross-sectional area: 0.5 mm.
Cable length: 0.3 m.
DC: Model.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connnectors meet IP67 reequirements and ensure a,
94V-0 fire retardant rating A22RW-3MA-24A-02.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnnector Assembly: Crimping, soldering, and screw-on A22RW-3MA-24A-02.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
A22RW-3MA-24A-02 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22RW-3MA-24A-02&select=5