Sensing method: Through-beam Sensors.
Appearance: Vertical.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: --.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Number of beams: 116.
Protective height: 2350mm.
Model: NPN.
Easy-to-use Safety Sensor Ideal for .
Simple On/Off Detection Applications A22TK-2LL-01-10.
Provides simple safety functions - saving TCO
A22TK-2LL-01-10
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Appearance: Standard.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON A22TK-2LL-01-10.
Indicator mode: Incident light .
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Series includes models that enable switching between,
dark-ON and light-ON operation.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for dark-ON,
operation are also available A22TK-2LL-01-10.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
havee enabled major savinngs in cost and space compared,
with previous systems A22TK-2LL-01-10.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems A22TK-2LL-01-10.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
A22TK-2LL-01-10 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22TK-2LL-01-10&select=5