Type: Reverse wiring.
Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Mounting method: Embedded with no screw threads.
Pin shape: Solder cup pin.
Applicable wire diameter: AWG22 to 28.
AC: Model.
Minimum order: 50 .
Water- and Environment-resistive FA A22TK-2LL-02-01.
Connectors Save Wiring and Maintenance Effort
A22TK-2LL-02-01
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available A22TK-2LL-02-01.
Three types of Connector Assembly: Crimping, soldering, and screw-on .
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Actuator: Plunger.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts A22TK-2LL-02-01.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Connection type: Screw - Screw.
Description: Controller link repeater unit (wire to wire).Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance A22TK-2LL-02-01.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set A22TK-2LL-02-01.