Classification: Equipped with operation indicator and diode to absorb coil surge.
Contact form: 4PST (standard).
Mounting method: Screw mounting .
Terminals: Connector.
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal Relay with 4 Independent.
Outputs.
Equipped with four G6B Mini-relays that are compact, highly sen,
sitive, and highly resistant to dielectric surges, and that can switch,
5 amps of power
A22TK-2LR-21-K01
Sealed plastic construction used for relays.
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate maintenance,
(except for high-reliability models).
UL and CSA certification for standard models,
(except for high-reliability models) A22TK-2LR-21-K01.
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 5 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding) A22TK-2LR-21-K01.
Separate Construction with.
Cylindrical 16-dia . Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Type: 1a1b welding terminal.
Shape: rectangle.
Type: General load.
Action: instantaneous action (auto recovery).
With light: LED with light.
Using voltage: DC12V.
Operation Department color: white.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easilyy because operation time,
is indicated from the start of operation A22TK-2LR-21-K01.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions A22TK-2LR-21-K01. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.