Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45) .
Cable length: 10 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V .
Output current: 3 A3DA-500R. 75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: Yes
A3DA-500R
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor A3DA-500R.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Name: MIL Connectors.
Specifications: Inputs;
32 inputs ; NPN; -- A3DA-500R.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Appearance: Unshielded, M18.
Sensing distance: 8 mm.
Output configuration: DC 3-wire, PNP.
Model: Operation mode, NC.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Side plunger, Adjustable.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) A3DA-500R.
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavaailable for complex operations A3DA-500R.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
A3DA-500R Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3DA-500R&select=5