Number of beams: 95.
Protective height: 960mm.
Model: PNP output.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Type: rectangle.
Screen mode: no segmentation .
Output: SPDT A3PA-5012.
Power supply voltage: DC12V.
Contact type: standard load (AC250V, 3A; DC30V, 3A)
A3PA-5012
Operation: alternating action (self retaining).
Operation Department color: green.
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing A3PA-5012.
LED has five colors (red, yellow, green, white, and blue) .
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Name: HFU with Programless Communications *1.
Power supply voltage: 24 VDC supplied from the End Unit A3PA-5012.
No . of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485.
Input type: No input.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventoory,
requirements A3PA-5012.
Connecct directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise .
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculaatee the PID constants with the step,
response method A3PA-5012.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
A3PA-5012 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3PA-5012&select=5