Name: Slice I/O Units; Digital I/O Units.
Specifications: 8 inputs PNP.
Standards: CE, UC1, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system .
A wide variety of CompoNet Slave Units,
contribute to system size reduction A3PA-90A21-24EWR.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site
A3PA-90A21-24EWR
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Output.
I/O points: 16 A3PA-90A21-24EWR.
Internal I/O circuit common: PNP (– common) .
Rated voltage: 12 VDC, 24 VDC.
Single Cable Connection to PLC Means.
Space is Saved and Less Control Panel.
Wiring is Required.
Compact size: 182 (W) 85 (D) 68 (H) mm,
(8-point Output Block width is 102 mm).
Connects to the PC through the connecting cable,
(G79 Series) and connector, and requires only a,
snap-in operation.
Surge suppressor circuit built-in A3PA-90A21-24EWR.
Immediate recognition of I/O signal status using,
LED operation indicators .
G3TA I/O Solid-state relay can be mounted instead,
of G7T.
Mounts easily on a DIN track.
Approved by UL, CSA (except for G7TC-OC16-1). Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Number of beams: 24.
Protective height: 480mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions A3PA-90A21-24EWR.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions A3PA-90A21-24EWR.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
A3PA-90A21-24EWR Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3PA-90A21-24EWR&select=5