Size: 48 x 96mm.
Control output 1: double relay (proportional valve).
Auxiliary (alarm) output: 4.
Transfer output: have.
Event input: 4.
Communication: RS-485.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications A7D-106-PM.
Can be set up to 8 procedures (mode) x 32 (step) procedure
A7D-106-PM
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set A7D-106-PM.
It can be easily set by CX-Thermo (sold separately) .
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control A7D-106-PM. Appearance: Rectangular (M16-J).
Lighting: LED without Voltage Reduction Unit, 5 VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Safety outputs: Instantaneous, DPST-NO; OFF-delayed, DPST-NO.
Auxiliary outputs: 1 (Solid-state).
Max. OFF-delay time: 30 s.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input. Power ratings: 15 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 0.65 A.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication moonitor that A7D-106-PM.
conform to UUL Class 2 Output standards .
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) A7D-106-PM.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
A7D-106-PM Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A7D-106-PM&select=5