Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: DPDT.
Lighting: LED; 12 VDC .
Pushbutton color symbol: R.O B3F-1006. G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity
B3F-1006
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Optical system: Diffuse reflective.
Beam shape: Line beam.
Sensing distance: 100±35mm.
Resolution: 5µm B3F-1006.
Stable, Easy & Affordable .
New Regular-reflective Sensor Head.
Designed for Optimal Wafer Measurement. Name: Expansion Units.
Specifications: Outputs;
8 outputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet B3F-1006.
Branching is easily made with CompoNet .
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: DC Power Supply Unit.
Power supply voltage: 24 VDC.
Output capacity: 5 VDC output capacity, 5.3A;
26 VDC output capacity, 1.3A;
Total, 40W.
Options: 24 V DC service power supply, No;
RUN output, No.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Throough the support software (VVer B3F-1006.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication B3F-1006.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
B3F-1006 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=B3F-1006&select=5