Terminals: Push-In Plus terminal blocks.
Type: Output *2.
Points: 16.
Internal I/O circuit common: PNP (- common).
Rated voltage: 24 VDC.
I/O Relay Terminals with 16 Points and,
Push-In Plus terminal blocks to,
Downsize Control Panels and Save Labor.
I/O Relay Terminals with 16 points to mount G2RV Slim I/O Relays .
Push-In Plus terminal blocks are used to save wiring work in,
comparison with traditional screw terminals
B3S-1100 (Wiring time is,
reduced by 60%* in comparison with traditional screw terminals.).
Work is reduced ever further with one-step cable connection to the PLC.
Diode provided for coil surge absorption.
Operation indicators for immediate recognition of I/O signal status B3S-1100.
Accepts G3RV Slim I/O SSRs.
DIN Track or screw mounting. Small, easy to use.
Detection method: Regression reflection type.
Shape: vertical type.
Connection mode: lead wire.
Detection distance: 1 meters of red light.
Output mode: PNP output. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input B3S-1100.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square rootss,
have enabled major savinngs in cost and space compared,
with previous systems B3S-1100.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems B3S-1100.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
B3S-1100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=B3S-1100&select=5