Name: Connector.
Model: C200H-CE001.Actuator: Roller lever (metal lever, bearing roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms CS1W-CN626.
(Slow-action models with MBB contacts are available
CS1W-CN626)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) CS1W-CN626.
Certified standards: UL, EN (TÜV), and CCC . Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance CS1W-CN626.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Power supply voltage: AC/DC power supply selectable type.
Sensing method: Retro-reflective without MSR function.
Sensing distance: 7 m[100 mm](When using E39-R1), 11 m[100 mm](When using E39-R2).
Output configu ration: Relay.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, RRetro-reflective: 7 m, andd,
Diffuse-reflective: 2 CS1W-CN626.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectaablle power supply input (24 to 240 VDC, 24 to 240 VAC) CS1W-CN626.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available.
CS1W-CN626 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=CS1W-CN626&select=5