Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function
D2MC-01FL
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance D2MC-01FL.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation D2MC-01FL.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc . , can be a key operation. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: SPDT.
Lighting: Incandescent lamp; 14 VDC/VAC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater conntrol methods,
including OON/OFF control, phase control, and cyclic control D2MC-01FL.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads D2MC-01FL.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
D2MC-01FL Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D2MC-01FL&select=5