Sensing method: Through-beam (Emitter + Receiver).
Connection method: Standard M8 connector.
Sensing distance: 30 m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models D2MSL13.
Mechanical axis and optical axis offset of less than ±2
D2MSL135° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1 D2MSL13. 2 V max. (0.5 ADC,
between each output terminal and the G terminal) .
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max D2MSL13.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-D.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Usingg a Ring) D2MSL13.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type D2MSL13.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
D2MSL13 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D2MSL13&select=5