Sensing method: Through beam.
Connection method (cable length): Pre-wired (2 m).
Sensing distance: 300 mm.
Beams: Gap, 25 mm; Qty, 3.
Sensingwidth: 50 mm.
Output type: NPN open collector.
Compact Body, High-visibility.
Indicators, and Ideal for Picking.
Systems for Small Parts.
A variety of part sizes can be handled: F3W-D sensing,
width: 100 mm, F3W-E sensing width: 50 mm D4F-102-1R.
Low-profile Sensor with thickness of 8 mm and enlargeable,
work opening
D4F-102-1R
Models with connectors are also available.
Support for XS5 Smartclick Connectors reduces work and,
simplifies wiring. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed pin plunger D4F-102-1R.
Cable length : 3 m.
Compact Limit Switch That''s Also .
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4F-102-1R.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output and long life.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventtive maintenance function is increased,
Further performance improvement D4F-102-1R.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV D4F-102-1R.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
D4F-102-1R Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4F-102-1R&select=5