LK166
Home >> Price >> MITSUBISHI >> AJ35PTF-56AR
Brand sort

MITSUBISHI AJ35PTF-56AR

Country: JAPAN
Name: AC input / relay output module
Model: AJ35PTF-56AR
Price: 0
MITSUBISHI AJ35PTF-56AR
Input points: 16 points.
Input voltage and current: 6mA DC24V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Common anode.
18 point terminal station.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings AJ35PTF-56AR. And there is no need to select the cable, the straight line and the cross line can be used AJ35PTF-56AR
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location AJ35PTF-56AR.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields AJ35PTF-56AR.
Can also be used in combination with the CPU module to achieve appropriate control .
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.Input points: 16 points.
Voltage: DC12/24V.
Current: 4/10mA.
Response time: 6ms/1ms (high speed mode).
8 points / a common end.
Negative utility.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
UUnder the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ35PTF-56AR.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ35PTF-56AR.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
AJ35PTF-56AR Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=AJ35PTF-56AR&select=5


...more relevant model market price >>>>
Related products