Length: 2m.
Specification: universal connection cable. Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: 6.0mA.
Response time: 5 S ~ 70ms.
Common way: 8 point / public end (negative public end).
Interrupt function: have.
External wiring connection mode: 18 point screw terminal .
The input module is the most used module in the control system FR-F842-10940-2-60.
According to the input voltage, the input points of different, choose the most suitable user needs of the module
FR-F842-10940-2-60
1 modules are equipped with a variety of functions.
Can be through a single input module to 1 points for the unit to set the high speed response, interrupt input function FR-F842-10940-2-60.
In addition, the public end of the module can be freely selected as the common end of the positive pole and the negative pole .
It is not necessary to use different modules according to the input specifications and functions, and reduce the number of modules,
Therefore slot occupied quantity can be reduced by 20% than in the past, the deployment cost can be reduced by 60% compared with the previous FR-F842-10940-2-60. Input and output points: 512 points .
Input / output data points: 512 points.
Program capacity: 8k.
Basic command processing speed (LD command) S:1.25.
RAM memory capacity: 32K,
Optical data communication line.
The popularization and application of PLC programming has been developed rapidly in our country,
It has been widely used in all kinds of mechanical equipment and production process of electrical control devices,
All walks of life have emerged a large number of application of PLC transformation of the results of the equipment.
Understand the working principle of PLC, have the ability to design, debug and maintain the PLC control system,
Has become the basic requirements of modern industry for electrical technicians and engineering students.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language. In large and medium-sized PLC systems, structured text is often used to describe the relationship between the variables in the control system.
Mainly used for oother programming languages more difficult to achieve the user program FR-F842-10940-2-60.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPUU FR-F842-10940-2-60.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
FR-F842-10940-2-60 Operation manual / Instructions / Catalog download link: