Terminal connectorConnecting cable for handheld RH GOT and PLC.
Cable length: 10 meters.
Application: RS-422 connection and RS-232C connection. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type HA-SH301.
Output points: 8 points.
OFF leakage current: 0.25mA.
Output protection function
HA-SH301
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool HA-SH301. Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: 6.0mA.
Response time: 5 S ~ 70ms.
Common way: 8 point / public end (negative public end).
Interrupt function: have.
External wiring connection mode: 18 point screw terminal HA-SH301.
The input module is the most used module in the control system.
According to the input voltage, the input points of different, choose the most suitable user needs of the module.
1 modules are equipped with a variety of functions.
Can be through a single input module to 1 points for the unit to set the high speed response, interrupt input function.
In addition, the public end of the module can be freely selected as the common end of the positive pole and the negative pole.
It is not necessary to use different modules according to the input specifications and functions, and reduce the number of modules,
Therefore slot occupied quantity can be reduced by 20% than in the past, the deployment cost can be reduced by 60% compared with the previous. Type of input: DC leakage.
Input points: 32 points.
Input voltage: DC24.
Input current: 7mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Anaalysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and coompllex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced HA-SH301 HA-SH301.
HA-SH301 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HA-SH301&select=5