Data communication line module (coaxial cable) Master / local station for A3VTS multiplex system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures .
Protection and chain is an indispensable part of the program, must be carefully considered
HF-JP103B
It can avoid the control logic confusion caused by illegal operations. Servo motor series: low inertia, medium / high power.
Rated output: 1.5kw.
Rated speed: 3000r/min.
Electromagnetic brake: with.
Shaft end specification: Standard (straight axis) HF-JP103B.
Features: low inertia for high speed / acceleration and deceleration operation occasions .
IP level: IP67.
Application example:
1, food processing machinery.
2, printing machine.
3, injection molding machine (11KW, 15KW).
4, large press machine (11KW, 15KW).
The protection level of the HF-SP/HF-JP series servo motor is IP67 (except the shaft part).
Low inertia of the power servo motor (0 HF-JP103B. 5kW ~ 9kW), the maximum speed: 6000r/min (rated speed: 3000r/min),
Suitable for high frequency positioning and acceleration / deceleration operations, especially for food processing machines and printing machines .
Low inertia, high power, no cooling fan servo motor (11kW and 15kW), maximum speed: 3000r/min (rated speed: 1500r/min).
The motor structure is more compact due to the adoption of the non cooling fan design, and the connection is reduced by using the power source connector.
(compared with the HF-LP series servo motor with the same power, the volume is reduced by about 46%, and the weight is reduced by about 34%,
Suitable for high frequency positioning and acceleration / deceleration operations, especially for injection molding machines and large presses.
HF-JP703 (4) /903 (4) maximum speed: 5000r/min. Differential output.
Axis of control: 4.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CCH data sampling HF-JP103B.
Among theem, the word 8CH, bit 8CH data can be displayed in real time .
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring innformation and monitor the display HF-JP103B.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
HF-JP103B Operation manual / Instructions / Catalog download link: