MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.1kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: single phase AC100V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier .
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed
LD77MH16
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS LD77MH16.
Security functions are connected to the CN8 interface through an external security circuit to increase the MR-J3-BS driver security.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version. Input: 4 channels.
Platinum resistance (Pt100; JPt100; Ni100) LD77MH16.
Conversion speed: 40ms/1 channel .
18 point terminal.
Isolation between channels.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detection function.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) withhout using the backup batterry,
To prevent the loss of the program and the parameters due to forgetting to replace the battery LD77MH16.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and ottheer planned downtime,
The data is lost due to battery depletion LD77MH16.
The next time the power is turned on, the backup data will be automatically restored.
LD77MH16 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=LD77MH16&select=5