Motor series: medium inertia, medium power.
Rated output power: 0.5kw.
Rated speed: 2000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: medium inertia from low speed to high speed three modes for selection, suitable for different applications .
Application examples: transmission machinery, robots, X-Y working platform MR-C10A1.
High resolution encoder 131072p/rev (17 bit)
MR-C10A1
The encoder with high resolution ensures excellent performance and stability at low speed.
All motor dimensions are the same as before and all are compatible with the wiring. Input and output points: 512 points.
Input / output data points: 512 points MR-C10A1.
Program capacity: 14K .
Basic command processing speed (LD command) s:0.20.
Optical data communication line function (GI cable).
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure MR-C10A1.
Modular: PLC is the basic components of a separate module .
Medium and large PLC used this way. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delaay MR-C10A1.
User program storage cappacity: it is a measure of how much the user application can store the number of indicators .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words MR-C10A1. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
MR-C10A1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-C10A1&select=5