Type: sensor connector (e-CON).
Output form: transistor output, source.
Output points: 16 points.
Rated input voltage / current: DC12/24V (0.5A).
External connection: 3 wire.
By using the output ON number of times, it is convenient to confirm the total number of ON of each output point.
High speed input and output control of a single module can be realized by using first order logic function MR-H20ACN.
IE CC-Link field network remote equipment station
MR-H20ACN According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module) MR-H20ACN.
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station . Cable length: 2m.
RS-485 terminal unit conversion unit.
Applicable model: GT16. Control axis: maximum 8 axes.
Teaching operation function: No.
To stop the speed control function at the specified location MR-H20ACN.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time.
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 2.2KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric ennergy MR-H20ACN.
Speed control methodd of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs off closure MR-H20ACN.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.