Power: 7.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor MR-J3-22KBS4. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor
MR-J3-22KBS4
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Total points: 60 points.
Input points: 36 points.
Output points: 24 points.
Voltage: AC220V.
Output type: relay MR-J3-22KBS4.
Outline dimension: 175*75*90 .
FX1N series is a very powerful micro PLC,
Can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect. Output type: relay.
Output points: 16 points MR-J3-22KBS4.
Load voltage: AC120/DC24.
Load current: 2A .
Connection mode: terminal row.
Common public end points: 8.
Sequential function flow chart language is designed to satisfy the sequential logic control.
The process of sequential process action is divided into steps and transformation conditions,
According to the transfer condition, the control system is distributed in the function flow sequence,
Step by step according to the sequence of actions.
Each step represents a control function, represented by the box.
In the box, the ladder logic is used to complete the task of the corresponding control function.
This programming language makes the program structure clear and easy to read and maintain,
Greatly reduce the programming workload, shorten the programming and debugging time.
Used in the system of the size of the school, procedures for more complex occasions.
Sequence function flow chart programming language features: to function as the main line,, in accordance with thee functional flow of the order of distribution, clear, easy to understand the user program,
Avoid the defect of ladder diagram or other languages,
At the same time, the use of ladder language to avoid the use of ladder programming,
Due to the compllicaated mechanical interlock, the structure of the user program is complex and difficult to understand,
User program scan time is also greatly reduced MR-J3-22KBS4 MR-J3-22KBS4.
MR-J3-22KBS4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J3-22KBS4&select=5