Input / output points: 2048 points.
Number of input and output elements: 8192.
Program capacity: 20 K step.
Processing speed: 0.04 s.
Program memory capacity: 80 KB.
Support USB and RS232.
Support installed memory card.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time
MR-J4-DU45KA4-RJ
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias MR-J4-DU45KA4-RJ.
High speed and high precision data processing .
The processing speed of the real number (floating point) arithmetic has been greatly improved,
Addition instruction reached 0.014 mu s,
Therefore, it can support the request of high-speed, high-precision processing data processing.
In addition, the new addition of double precision floating point arithmetic instructions,
Simplify the programming, reduces the computational error when executing complex formula MR-J4-DU45KA4-RJ. Total points: 20 points.
Input points: 12 points.
Output points: 8 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 75*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0.
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 1.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase mootor? Can single phaase power supply be used?
Basically can not be used MR-J4-DU45KA4-RJ. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor exxplosion will be induced MR-J4-DU45KA4-RJ.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.
MR-J4-DU45KA4-RJ Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J4-DU45KA4-RJ&select=5