E32-T333-S5 type: special beam type; ultra small / small diameter beam,
Specialty: Phi 0.25 casing,
Open diameter: 0.125,
Shape / detection distance (mm): 12; 10; 6 (4),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 0.125 (0.005),
Fiber element for meeting diversified needsPower supply voltage: 24V DC±10%, Ripple (p-p): 10% 3G2A5-COV11.
Current consumption: 1.2A max.
Discharge voltage: ±7
3G2A5-COV115kV.
Discharge method: Variable DC.
Ionization time: 1 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red) 3G2A5-COV11.
Main functions: Ion balance adjustment (Automatic and manual) .
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0.1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing) 3G2A5-COV11.
Ambient humidity range: 35% to 65% (No icing or dewing) .
Weight (Packaged): Approx. 1 kg (Approx. 1.8 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, Stand, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues. Output: DPDT.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily mmade with CompoNet 3G2A5-COV11.
Wiriing material cost can be reduced .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . 3G2A5-COV11.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
3G2A5-COV11 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=3G2A5-COV11&select=5