LK166
Home >> Price >> OMRON >> 3G3EV-A1002
Brand sort

OMRON 3G3EV-A1002

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Model: 3G3EV-A1002
Market price: U.S.$ 705.42
(The following are the market open price not sales price!)
OMRON 3G3EV-A1002
Measurement range: 5 mm.
Output specifications: B7A serial communications output (See note 2.).
Actuator: Pin type.
Resolution: 1 µm.
Contact Displacement Sensor with Built-in.
Amplifier That Enables In-line Measurement.
of a Wide Range of Objects with a Low.
Operating Force.
Works with a low operating force (0 . 29 N) to detect a wide vari,
ety of objects including glass, plastic, and rubber objects 3G3EV-A1002
Models with digital output for B7A Units and models with 4- to,
20-mA linear output corresponding to the 0- to 5-mm measure,
ment range are available.
Models with ball-, flat-, or pin-type actuators are available for a,
wide variety of objects.
The XS3 Sensor I/O Connector makes Sensor connections simple 3G3EV-A1002. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use 3G3EV-A1002.
Event input points: - .
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Prevents Equipment Stoppage, Data Loss,
and Other Problems Resulting from Momentary.
Powerr Failures 3G3EV-A1002.
Provides a bbackup time of 500 ms at an output current of 2 .5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
Parallel connections to up to four Blocks can be used to increase,,

the backup time and current capacities 3G3EV-A1002.
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C.
3G3EV-A1002 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=3G3EV-A1002&select=5


...more relevant model market price >>>>
Related products
Related download