Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function .
Event entry point: 4.
Transfer output: transfer output (special terminal) 3G3JV-A4015.
Remote SP:4 to 20mA input
3G3JV-A4015
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 3G3JV-A4015. 01 degrees C .
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver 3G3JV-A4015. 4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output .
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. CPU Unit: Units with 10 I/O points.
I/O terminal block.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: relay.
Internal clock: --.Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible 3G3JV-A4015.
The electrodee side terminals and other wiring terminals are separated, so the wiring operation is simple .
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
Type: G3N type, both full of water, water sshoortage alarm function of automatic supply and drainage 3G3JV-A4015.
Package product name: 61F-G3N base * 1, 61F-11_ unit * 3.
Purpose: long distance use (2km).