Actuator: Roller lever: R38.
Item: High-precision.
Connector shape: Threaded (M12).
Built-in switch type: Airtight.
Voltage: DC.
Wiring locations: NO only 2 core.
Connector pin No: NO 1 4 .
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches
42662-0100 QBR-10
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting 42662-0100 QBR-10.
Approved standards: EN/IEC, UL, cUL, and CCC .
Contact your OMRON representative for information on approved models. Measure High-speed Up/down Pulses with this.
Up/down Pulse Meter.
Visual conf0rmation of judgement results through display colors that,
switch between red and green.
Perfect for Measuring Rotary Encoder and ON/OFF Pulse Signals at High Speed,
Cumulative pulse input is 50 kHz, quadrature pulse inputs are 25 kHz,
and up/down pulse inputs are 30 kHz 42662-0100 QBR-10.
Note: No-voltage contacts of up to 30 Hz are supported.
The count value can be converted to any value.
The length equivalent for any pulse can be set to any desired value. This is,
effective for feed amount and position monitor displays.
DeviceNet models added to the series. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventivve maintenance funcction is increased,
Further performance improvement 42662-0100 QBR-10.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV 42662-0100 QBR-10.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
42662-0100 QBR-10 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=42662-0100 QBR-10&select=5