Type: M8.
Actuator: Wobble stick actuator; Short spring.
Cable length: 5 m.
Detects Objects in Multiple Directions,
with High Sensitivity, Ideal for Robotics,
Slow-action switching mechanism used.
Gold-plated contact with coil spring capable of switching,
micro current/voltage load while providing high contact reliability .
Inputs directly to microcomputers and programmable controllers 44533-1160 T4011-L031MF1N.
Three sizes (M10, M8, and M5) and three types of compact actuators
44533-1160 T4011-L031MF1N
Easy panel mounting. Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white 44533-1160 T4011-L031MF1N.
Item: Alternate operation (Self-holding) .
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Unit name: Loop Control Boards 44533-1160 T4011-L031MF1N.
Specifications: No. of function blocks:
500 blocks max.
Standards: UC1, N, CE .
The open nature of the PLCs is joined,
by integrating hardware, software,
and networking to meet your needs.
Increasing amounts of information,
standardization, and open standards,
form the basis for achieving hardware,
and networking capabilities for process control.
A wide range of software that can be easily,
used by design, development, and maintenance,
personnel makes operating and maintaining,
the system far easier. E32-T81F-S type: resistant to environmental type; resistant to drugs,
Specialty: Teflon coating heat: 200 degrees,
Shape / detection distance (mm): 920; 700; 460 (190),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsNo. of steps: 12.
Rated voltage: 24 VDC, 100 VAC, 200 VAC.
Ideal for Controlling Pumps and Production.
Lines with Six or Twelve Stepping Circuits.
Built-in relays switch 2 A at 250 VAC or 30 VDC.
Initialization of stepping with reset input.
Uses memory that stores setting status for 10 days without.
power. All internal contacts are releaseed when no power is supplied 44533-1160 T4011-L031MF1N.
Detects an internal element malfunction caused by external.
noise, indicates the malfunction with an alarm indicator, and,
turns the relay alarm output ON. (An internal relay malfunction,
or internal relay contact weld cannoot be detected 44533-1160 T4011-L031MF1N. ).
With safety-design terminals which prevent electric shock accidents.
With easy-to-see indicators which display the stepping status.
44533-1160 T4011-L031MF1N Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=44533-1160 T4011-L031MF1N&select=5