LK166
Home >> Price >> OMRON >> 51700-0190 KEY10(S)
Brand sort

OMRON 51700-0190 KEY10(S)

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Market price: U.S.$ 110.44
(The following are the market open price not sales price!)
OMRON 51700-0190 KEY10(S)
Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 8 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Function: Temperature monitoring.
Power supply voltage: 24 VAC/DC .
Monitor Temperature Rise through.
Internal Motor Loss 51700-0190 KEY10(S).
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22 51700-0190 KEY10(S)5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits 51700-0190 KEY10(S).
Manual or automatic resetting with the same Relay. Input capacity: 16 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: PNP.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max 51700-0190 KEY10(S).
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow) .
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CCON connectors 51700-0190 KEY10(S).

A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
swwittch and with tool software 51700-0190 KEY10(S).
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.

51700-0190 KEY10(S) Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=51700-0190 KEY10(S)&select=5


...more relevant model market price >>>>
Related products
Related download