Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Automatic.
Output: SPST-NO + SPST-NO.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia . or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit 61F-G4NL AC110/220 2KM.
Finger protection mechanism on Switch Unit provided as a standard feature
61F-G4NL AC110/220 2KM
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models) 61F-G4NL AC110/220 2KM.
IP65 (lighted models). Appearance: Square/Projection type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-C .
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring) 61F-G4NL AC110/220 2KM.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily becauuse operation time,
is indicated from the start of operation 61F-G4NL AC110/220 2KM.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions 61F-G4NL AC110/220 2KM. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
61F-G4NL AC110/220 2KM Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=61F-G4NL AC110/220 2KM&select=5